Home » News » Company News » Ventilation plate-related introduction and explanation

Ventilation plate-related introduction and explanation

Views: 0     Author: Site Editor     Publish Time: 2024-01-18      Origin: Site

Inquire

facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button
Ventilation plate-related introduction and explanation

The sticking of the Ventilation plate should adopt the strip sticking method or point sticking method, and the glued area should not be less than 50%. After the adhesive is applied to the Ventilation plate, the lower end of the insulation plate should be attached to the base layer first. The Fire insulation board should be laid horizontally from bottom to top along the horizontal direction and should be anchored while laying, and the joints of the plates should be naturally tight. The gap between the boards shall not be greater than 2mm. If the gap is 2mm wide, it shall be filled with thermal insulation material. Adjacent board surfaces should be flush, and the height difference between boards should not exceed 1.5mm. Next, let's take a look at the introduction and description of the Ventilation plate.


Here is the content list:

Construction and installation of Ventilation plate

What are the main advantages of a Ventilation plate?


Construction and installation of Ventilation plate


1. Construction preparation


Before the Ventilation plate leaves the factory, the plane size, length, thickness, steel bar spacing, etc. of the plate should be checked. After meeting the requirements of the design drawings and issuing a product qualification certificate, after the wallboard arrives at the construction site, the quality inspector must test the relevant quality indicators of the wallboard. The thickness of the External wall fire insulation board is measured with a caliper, and the size of the section is measured with a tape measure, and compare the measured values with the design drawings. Check the steel lining spacing and take samples if necessary to complete destructive testing. Destructive testing allows visual inspection of scrims, linings, fiberglass, anti-crack protection, and material performance to determine whether requirements are met.


2. Laying out


According to the vertical control line of the structure, use the line pendant to do the setting-out work of vertical positioning, and use the plane control line as the standard to determine the position of the component entering and exiting the positioning line with a tape measure. After determining the position of the finished line, compare it with the original Ventilation plate design drawing. The main content of the check is the size and wheelbase. After checking and confirming that it is correct, set the vertical center line on the edge of the floor. Then, the main structure of the building is verified, mainly checking whether the actual elevation is within the error range of the design elevation. And mark the elevation of each floor at the edge of the floor, which is convenient for checking when the components are installed.


3. Welding and fixing connection parts


Check the positioning lines of the components of the Ventilation plate, and install the connecting corners according to the positioning lines. The connection corner code adopts a special T-shaped steel plate connector, and the size and size are made or ordered according to the requirements of the drawing. One end is welded to the concrete reinforcement skeleton embedded part at the end of the slab rib. The other end is welded to the beam-slab column of the main structure frame or the ring beam at the floor or the embedded part on the seismic structural column.


What are the main advantages of a Ventilation plate?


1. Ventilation plate is environmentally friendly, non-toxic, and harmless. The Roof insulation board does not contain any toxic ingredients, or foaming agents, and various admixtures have no volatile harmful substances. Therefore, the Ventilation plate is beneficial to the indoor environment.

2. Ventilation plate is stronger than polyfoam.

3. The use cost of the Ventilation plate is lower, which has obvious economic advantages.

4. Ventilation plate has high heat resistance. Ventilation plate heat resistance can reach above 500℃, there is no thermal decomposition, so the service life is longer, and it will not cause insulation failure.

5. Ventilation plate is fast in construction and can be laid directly.


Committed to bringing more and better products to customers, this is what we have been doing. If you are interested in our Steam pipe insulation board products or have other needs, you can contact us, our website is https://www.wt-insulation.com/, welcome your arrival and look forward to cooperating with you. Adhering to the corporate culture of "quality first, customer first", our company has always made unremitting efforts to become a professional Ventilation plate supplier in the industry.


Related News

W.T Thermal Insulation Material Co., Ltd. is an innovative enterprise, focus on research and manufacturing. With the cohesion and forward-looking awareness of our management team, we became to the modern enterprises.

QUICK LINKS

CONTACT US

 No.5,North Waihuan Road,Huang tang Development Zone,Xuxiake Town,Jiangyin City,Jiangsu Province,China 214407
+86-13771601681
 +86-13771601681
wtlb-alice
Leave a Message
Contact Us
Copyright © 2021 W.T Thermal Insulation Material Co.,Ltd. All Rights Reserved.
Sitemap | Support By Leadong